JCL z/OS DFSMS - IEBGENER In-stream Input, Sequential Data Set to Tape Volume



Desenvolvido por DORNELLES Carlos Alberto - Analista de Sistemas - Brasília DF. - cad_cobol@hotmail.com

JCL z/OS DFSMS - IEBGENER Example 4: In-stream Input, Sequential Data Set to Tape Volume

DFSMS (Data Facility Storage Management Subsystem) - 2.4.0


In this example, an in-stream input, sequential data set is copied to a tape volume.
Este exemplo, uma entrada in-stream, conjunto de dados sequenciais é copiado para um volume de fita.

  //CDTOTAPE JOB  ...
  //STEP1    EXEC PGM=IEBGENER
  //SYSPRINT DD  SYSOUT=A
  //SYSIN    DD  DUMMY
  //SYSUT2   DD  DSNAME=OUTSET,UNIT=tape,LABEL=(,SL),
  //             DISP=(,KEEP),VOLUME=SER=001234,
  //             DCB=(RECFM=FB,LRECL=80,BLKSIZE=2000)
  //SYSUT1   DD  *
  (in-stream data)
  /*

The job control statements are as follows:
As declarações de controle de trabalho são as seguintes:

  • SYSIN DD defines a dummy data set.
    No editing is performed; therefore, no utility control statements are needed.
  • SYSUT2 DD defines the output data set, OUTSET.
    The data set is written to a tape volume with IBM standard labels.
    The data set is to reside as the first (or only) data set on the volume.
  • SYSUT1 DD defines the in-stream data which is actually a JES SYSIN data set.
    The data set contains no statements.

  • SYSIN DD define um conjunto de dados fictício.
    Nenhuma edição é executada; portanto, nenhuma instrução de controle de utilitário é necessária.
  • SYSUT2 DD define o conjunto de dados de saída, OUTSET.
    O conjunto de dados é gravado em um volume de fita com rótulos padrão IBM.
    O conjunto de dados deve residir como o primeiro (ou único) conjunto de dados no volume.
  • SYSUT1 DD define os dados in-stream que são, na verdade, um conjunto de dados JES SYSIN.
    O conjunto de dados não contém declarações.

Parent topic: IEBGENER Examples



© Copyright IBM Corp.